Home    Anode Materials    Lithium battery anode material MCMB high capacity, high rate and long cycle

Lithium battery anode material MCMB high capacity, high rate and long cycle

  • 微信号:batteryhk

Contact
  •        AFT-MCMB-RB is an upgraded product of mesophase carbon microspheres that takes into account magnification, capacity, long cycle life, low pole piece rebound, excellent electrolyte compatibility, excellent processing performance, and excellent safety. In the process of ball formation, the method of inserting and fusing the plane molecular layers into each other is changed to make AFT-MCMB-RB form a stronger internal solid structure. After graphitization at 3200℃ ultra-high temperature, the purity of the product is improved and the impurity content is reduced. Finally, AFT-MCMB-RB is better than other MCMBs with the same particle size distribution, taking into account magnification and capacity, and has small pole piece rebound, long cycle life, excellent electrolyte compatibility, excellent processing performance, high safety, etc. Features, suitable for various types of lithium-ion batteries in power, power tools, 3C digital and other fields.

     

    Item Unit Specification Typical value Instrument/Method 
    Particle Size D10 μm 7.0±2 7.8 Laser particle size analyzer/MASTERSIZER2000
    Particle size analysis-Laser diffraction method
    D50 11.5±2.5 12.1
    D90 20.5±4.5 21.3
    Tap Density g/cm3 ≥1.15 1.24 Tap Density Meter/DAT-3
    Metallic powdersdetermination of tap density
    Surface Area m2/g ≤3.5 2.95 American Quantachrome NOVA-4000E Determination of the specific surface area of solids by gas adsorption using the BET method
    Discharge Capacity  mAh/g ≥ 350 351.3 Half battery test, American Arbin multi-channel battery test system, Germany Braun company labstar (1200 / 780) glove box 0.6ma to 5.0mV, 0.3mA to 5.0mV; 0.6ma to 2.0V
    First Discharge Efficiency % ≥ 92 93.2
    Fixed carbon content % ≥ 99.95 99.96 Box type resistance furnace
    Method for chemical analysis of graphite
    Moisture Content % ≤ 0.20 0.02 Coulometric titration moisture meter
    determination of moisture content in chemical products Karl Fischer method
    Ash Content % ≤ 0.05 0.02 Gravimetric method, sample size 2g, muffle furnace 800 degrees, 5 ~ 6 hours to constant weight

     

    Scanning electron micrograph

     

     

    Charge and discharge curves

     

     

     

    Pressed density

     

     

     

    Battery sheet absorption time

     

     

    Discharge C rate

     

     

    Cycle performance

     

     

     

     

    Storage Condition

     

    1、Suggest storage temperature and humidity controlled below 40 ℃ and 60 %RH, respectively, for brandnew; After opening, please use it up as soon as possible.
    2、After opening for 1 hour, it is a natural phenomenon for moisture regain, implying that moisture content of powder could be increased to 3000 ppm. Suggest drying it again before use.

Model Number:AFT-MCMB-RB
Delivery Time:In Stock