Home    Anode Materials    Lithium battery anode material MCMB high capacity, high pressure, high energy density

Lithium battery anode material MCMB high capacity, high pressure, high energy density

  • 微信号:batteryhk

Contact
  •        AFT-MCMB-GR is an upgraded product of mesophase carbon microspheres with high capacity, high pressure, long cycle, excellent electrolyte compatibility, excellent processing performance, and high safety. After AFT-MCMB-GR has passed high temperature graphitization , Improve the purity of the product, reduce the impurity content, and then undergo the modification technology of mesophase carbon microsphere morphology, so that AFT-MCMB-GR has a higher capacity and higher compaction than ordinary MCMB. It also takes into account the long cycle life of MCMB, excellent electrolyte compatibility, excellent processing performance, and high safety. It is suitable for various types of lithium-ion batteries in power, energy storage, 3C digital and other fields.

     

    Item Unit Specification Typical value Instrument/Method 
    Particle Size D10 μm 11 - 15 13.1 Laser particle size analyzer/MASTERSIZER2000
    Particle size analysis-Laser diffraction method
    D50 19 - 23 21.2
    D90 32 - 38 35.7
    Tap Density g/cm3 ≥ 1.30 1.38 Tap Density Meter/DAT-3
    Metallic powdersdetermination of tap density
    Surface Area m2/g ≤ 1.2 0.98 American Quantachrome NOVA-4000E Determination of the specific surface area of solids by gas adsorption using the BET method
    Graphitization Degree % ≥94.5 95.3 PW3040/60 XRD diffractometer of PANalytical B.V., Netherlands; X-ray diffraction analysis method
    Discharge Capacity  mAh/g 355.0±2.5 356.2 Half battery test, American Arbin multi-channel battery test system, Germany Braun company labstar (1200 / 780) glove box 0.6ma to 5.0mV, 0.3mA to 5.0mV; 0.6ma to 2.0V
    First Discharge Efficiency % ≥92.0 93.9
    Fixed carbon content % ≥ 99.9 99.96 Box type resistance furnace
    Method for chemical analysis of graphite
    Moisture Content % ≤ 0.10 0.02 Coulometric titration moisture meter determination of moisture content in chemical products Karl Fischer method
    Ash Content % ≤ 0.05 0.02 Gravimetric method, sample size 2g, muffle furnace 800 degrees, 5 ~ 6 hours to constant weight

     

    Scanning electron micrograph

     

     

    Charge-Discharge Curves

     

     

     

    Pressed density

     

     

     

    Battery sheet absorption time

     

     

     

    Discharge C rate

     

     

     

    Storage Condition

     

    1、Suggest storage temperature and humidity controlled below 40 ℃ and 60 %RH, respectively, for brandnew; After opening, please use it up as soon as possible.